Quick-start manual
Trimix Analyser Connector
One-page setup and day-to-day guide. Read the section in your language before the first
use, then always compare the label with the analyser display before using the gas.
Important
The adapter copies readings and prints labels; it does not verify the gas. Confirm O2,
He, MOD/END, date, and cylinder marking on the analyser before diving.
Required before live readings
Enable the analyser data output first.
-
Zuerst: Datenausgabe einschalten.
Am Analyser
Menü → Preferences → Send Data to USB → On wählen. Manche Versionen nennen es Data output. Ohne diese Einstellung erhält der Adapter keine Messwerte. Den genauen Menühinweis beschreibt die offizielle Divesoft He/O2-Anleitung, Kapitel 12.
-
Mit dem Setup-WLAN verbinden.
Wähle
TrimixAdapter-XXXX, Passwort 12345678, und öffne http://192.168.4.1. Das XXXX ist die Endung der Geräte-ID.
-
AP nach einer Minute.
Das Setup-WLAN schaltet sich standardmäßig nach 60 Sekunden ohne Web-UI-Aktivität ab, um Strom zu sparen. Es bleibt aus, wenn kein gespeichertes WLAN vorhanden ist. Fünf kurze Pausen des Datenstroms innerhalb von 15 Sekunden starten es wieder. Eine Pause von mindestens der eingestellten Druckzeit (standardmäßig 2 Sekunden) löst weiterhin sofort einen Druck aus und zählt nicht als AP-Geste.
-
Drucker koppeln.
Im Web-UI unter Drucker nach dem eingeschalteten Niimbot B1/B21 suchen, ihn auswählen und speichern. Die Kopplung erfolgt über Bluetooth; die Verbindung zum Setup-WLAN ist nur für die Konfiguration nötig.
-
Zeit und Datum.
Für ein Datum auf dem Etikett die Uhr einmal einrichten: Normalerweise genügt eine WLAN-Verbindung (NTP). Bei einer eingebauten DS3231-RTC können Datum und Uhrzeit auch im Web-UI gesetzt werden. Ohne gültige Uhrzeit druckt das Gerät „Today“ statt eines erfundenen Datums.
-
Etikett drucken.
Nach mindestens fünf Sekunden stabilen Messdaten die Analyse am Analyser prüfen und die Ausgabe für die eingestellte Dauer pausieren (Standard: 2 Sekunden). Das erzeugt ein Etikett. Ein optionaler externer Taster druckt beim Loslassen ebenfalls die aktuelle, gültige Messung. Während des Druckens nicht erneut auslösen.
LED-Anzeige
- Violett
- Setup-WLAN aktiv; blinkend beim Start.
- Grün
- Mit gespeichertem WLAN verbunden; kurzer grüner Blitz nach erfolgreichem Druck.
- Blau
- Blinkend: Drucker wird verbunden. Dauerhaft: Etikett wird übertragen.
- Gelb
- Pause vor dem Druck zählt herunter; blinkend kann es fehlende Analyserdaten anzeigen.
- Rot
- Fehler; blinkend bei einem behebbaren Verbindungs- oder Druckfehler.
- Schwaches Weiß
- Gerät eingeschaltet, aber weder WLAN noch Setup-AP aktiv.
Falls die physische LED andere Farben zeigt, im Web-UI unter Einstellungen die LED-Reihenfolge GRB oder RGB wählen.
English
Quick-start guide
-
First: enable data output.
On the analyser select
Menu → Preferences → Send Data to USB → On. Some versions call it Data output. Without this setting the adapter receives no readings. The exact menu is documented in the official Divesoft He/O2 manual, section 12.
-
Join the setup Wi-Fi.
Select
TrimixAdapter-XXXX, enter password 12345678, then open http://192.168.4.1. XXXX is the end of the device ID.
-
AP one-minute timeout.
By default, the setup Wi-Fi turns off after 60 seconds without Web UI activity to save power. It stays off when no saved Wi-Fi is available. Five short data pauses within 15 seconds turn it back on. A pause at least as long as the configured print delay (2 seconds by default) still prints immediately and is never treated as an AP gesture.
-
Pair a printer.
In the Web UI, open Printer, scan for the powered-on Niimbot B1/B21, select it and save it. Pairing uses Bluetooth; setup Wi-Fi is only needed for configuration.
-
Time and date.
Set the clock once if you want a date on the label: normally, connecting to Wi-Fi is enough because it uses NTP. If a DS3231 RTC is fitted, you can also set the date and time in the Web UI. With no valid time, it prints “Today” rather than an invented date.
-
Print a label.
After at least five seconds of stable readings, check the analysis on the analyser and pause its data output for the configured duration (2 seconds by default). This sends one label. An optional external button also prints the current valid reading when released. Do not trigger another print while one is in progress.
LED meaning
- Purple
- Setup Wi-Fi active; flashes while starting.
- Green
- Connected to saved Wi-Fi; briefly flashes after a successful print.
- Blue
- Flashing: connecting to printer. Solid: sending label data.
- Yellow
- Pause-before-print countdown; flashing can indicate that analyser data has stopped.
- Red
- Error; flashes for a recoverable connection or printing error.
- Dim white
- Powered on, with neither normal Wi-Fi nor the setup AP active.
If the physical LED shows the wrong colours, select the correct GRB or RGB LED order in the Web UI settings.
Nederlands
Beknopte handleiding
-
Eerst: data-uitvoer inschakelen.
Kies op de analyser
Menu → Preferences → Send Data to USB → On. Sommige versies noemen dit Data output. Zonder deze instelling ontvangt de adapter geen meetwaarden. Zie de officiële Divesoft He/O2-handleiding, hoofdstuk 12.
-
Verbind met de setup-wifi.
Kies
TrimixAdapter-XXXX, gebruik wachtwoord 12345678 en open http://192.168.4.1. XXXX is het laatste deel van de apparaat-ID.
-
AP-time-out na één minuut.
De setup-wifi schakelt standaard na 60 seconden zonder Web-UI-activiteit uit om stroom te besparen. Hij blijft uit wanneer er geen opgeslagen wifi beschikbaar is. Vijf korte pauzes in de datastroom binnen 15 seconden starten hem opnieuw. Een pauze die minstens zo lang duurt als de ingestelde printvertraging (standaard 2 seconden) drukt nog steeds meteen af en telt niet als AP-gebaar.
-
Printer koppelen.
Open Printer in de Web-UI, zoek naar de ingeschakelde Niimbot B1/B21, kies hem en sla op. Het koppelen verloopt via Bluetooth; de setup-wifi is alleen nodig voor de configuratie.
-
Tijd en datum.
Stel de klok één keer in als u een datum op het etiket wilt: meestal is verbinden met wifi genoeg, omdat NTP wordt gebruikt. Met een geplaatste DS3231-RTC kunt u datum en tijd ook in de Web-UI instellen. Zonder geldige tijd drukt het apparaat “Today” af in plaats van een verzonnen datum.
-
Etiket afdrukken.
Controleer na minstens vijf seconden stabiele meetwaarden de analyse op de analyser en pauzeer de data-uitvoer voor de ingestelde duur (standaard 2 seconden). Er wordt één etiket verzonden. Een optionele externe knop drukt bij loslaten eveneens de actuele geldige meting af. Start geen tweede afdruk terwijl de eerste bezig is.
Betekenis van de led
- Paars
- Setup-wifi actief; knippert tijdens het starten.
- Groen
- Verbonden met opgeslagen wifi; korte flits na een geslaagde afdruk.
- Blauw
- Knipperend: verbinding maken met printer. Vast: labelgegevens worden verzonden.
- Geel
- Aftellen vóór afdrukken; knipperen kan aangeven dat analysergegevens zijn gestopt.
- Rood
- Fout; knippert bij een herstelbare verbindings- of printfout.
- Zwak wit
- Apparaat is ingeschakeld, maar normale wifi en setup-AP zijn beide niet actief.
Toont de fysieke led de verkeerde kleuren, kies dan in de Web-UI-instellingen de juiste led-volgorde: GRB of RGB.